Search
X

Search this site

Hotline phone 0 800 500 511
  • UA
  • RU
  • EN
  • UA
  • RU
  • EN
BTS Group
  • Equipment
    • Compressors
      • Oil-Injected Compressors
        • Direct-Drive Compressors
        • V-DRIVE T Variable-Speed Compressors
        • G-DRIVE T Two-Stage Compressors
      • Oil-Free Compressors
        • A-O Series
        • LENTO Series
        • Scroll Compressors
        • Low-Pressure Compressors
      • Reciprocating Compressors
        • Booster Compressors
        • HL/HLD Series up to 40 bar
        • HP Series up to 400 bar
        • A Series up to 10 bar
      • Centrifugal Compressors
      • Blowers and Gas Compressors
      • Turbo Blowers
      • Blowers
    • Gas Generators
      • Nitrogen
      • Hydrogen
      • Oxygen
    • Compressed Air Treatment
      • Air Dryers
        • Adsorption Dryers
        • Zero-Loss Compressed Air Dryers
        • Refrigerated Dryers (+3 °C)
      • Filters
    • Chillers
      • Hyperchill Smart-E
      • Hyperchill Plus-E
    • Monitoring and Measurement
      • Gas Analyzers
      • Gas Mixers
      • Flow Meters
  • Company
    • About Us and Our Partners
    • Contacts
    • Vacancies
      • Dnipro
        • Service Engineer
        • Sales Manager
      • Lviv
        • Sales Manager
    • News
    • Articles
  • Solutions
    • Nitrogen Generation
    • Modular Stations
    • Heat Recovery
  • Service
    • Maintenance
    • Airend Repair
    • Dryer Repair
    • Components and Spare Parts
  • BTS Group
  • Solutions
  • Heat Recovery
  • Nitrogen Generation
  • Modular Stations
  • Heat Recovery

Heat Recovery

Thermal Recovery

Easy to save energy and quickly get financial benefits

The energy used to produce compressed air is almost completely converted into heat. This is a high potential for energy saving. So, for example, one compressed air station with a consumed power of 75 kW for 4,000 hours of work will need about 300,000 kW of electricity a year.

This energy can be used in the following forms:

  • Heat air for additional heating;
  • warm water to support central heating;
  • Hot water for industrial water.

 

Hot air for the room

Heated cooling air is used to heat the room through the wind pipeline system. Temperature control valves provide a regulated temperature in the room. In winter, heat from the empty air is used entirely or partially for burning purposes. In summer, it is empty into the air through the drawing channel.

Hot water to support central heating

For the production of hot water, the plate heat exchangers are used. The polluting water passes through the "plast" in a closed body. The hot compressor oil flows between the plants and the body and supplies its heat energy to hot water. The temperature of hot water is permitted: up to 70 ° C.

Heat for water and technology

The process of heat regeneration is the same as for water heating. To prevent oil from penetrating into the work water, skin tubes are used. Working fluid temperature is permitted: up to 70 ° C.

Integrated heat recovery

All the components needed for heat recovery are installed in the compressor during the production process.

The advantages:

  • Just connect to the building and start saving immediately.
  • regulation of constant temperature: Depending on the available heat, the water temperature by the consumer will beined at the desired level.

Integrated heat recovery is available for compressors:

15 - 355 kW

Preparation for heat recovery

When ordering a new compressor, preparation can be made for the further installation of the heat recovery system, i.e.:

  • ball valves on the output from the oil side;
  • the space required for heat exchangers must be compatible with the plant;
  • the opening for connections must be pre-sweated in the panel;
  • The equipment can be completed without any costs later using the re-equipment set. This takes the installation:
    • The heat exchanger;
    • Temperature control + temperature sensor;
    • a hose connector / coupling.

 Heat Recovery for Old Compressors

External modules are required to equip previously installed compressors.

The advantages:

  • Connecting to all compressors;
  • The previously installed compressor is fully equipped with all the necessary high-efficiency components and secure devices;
  • Minimum installation costs thanks to the ALMiG Intellectual Design;
  • Continuous temperature regulation.

 The heat recovery for old compressors is available for:

4 to 355 kW.

 

Lorraine 

 

M isKyiv, 02660,
and vol.Redness 42,
tel/fax (044) 224 50 94
e-mail: kiev@btsgr.com.ua

M is Odesa, 65003,
The Black Sea Count 115
tel./fax (048) 734 01 45
e-mail: odessa@btsgr.com.ua

M is Dnipro, 49041,
Starting 20
tel/fax (056) 794 35 93
e-mail: dnepr@btsgr.com.ua

M is Harvard, 61054,
Vol. Vasilij Stusa 4a
tel. (057) 763 20 85
Fax (057) 756 35 45
e-mail: kharkov@btsgr.com.ua

M is Lviv, 79037,
Vol. Litvinenko, 3 office 318
tel/fax (032) 232 29 65
e-mail: lviv@btsgr.com.ua

  • Equipment
    • Compressors
    • Compressed Air Treatment
    • Chillers
    • Monitoring and Measurement
  • Solutions
    • Nitrogen Generation
    • Modular Stations
    • Heat Recovery
  • Service
  • Company
    • Vacancies
    • About Us and Our Partners
    • Contacts
    • News

Learn more about our other areas of expertise

hydro-part.com.ua

parkerstore.com.ua

mannfilter.com.ua

copyright 2026 BTS Group